- Speed to Power
- The time from site control to energized capacity at a data center campus. Developers now rank sites and partners on it, because utility interconnection, substation construction, and equipment lead times often set the schedule more than the building does.
- Large-Load Interconnection
- The utility process for connecting a new customer load of tens to hundreds of megawatts. It includes load studies, transmission or substation upgrades, and in many territories a large-load tariff with minimum-take, collateral, and contract-term provisions.
- Behind-the-Meter Generation
- Power produced on or next to the customer's site, such as natural gas turbines, reciprocating engines, or fuel cells, that serves the load before or alongside utility supply. Developers use it to energize capacity while grid interconnection is pending.
- Interconnection Queue
- The list of generation and load requests waiting for study and approval by a grid operator or utility. FERC Order No. 2023 moved transmission providers to a first-ready, first-served cluster study process for generator interconnection.
- PUE (Power Usage Effectiveness)
- The ratio of total facility power to IT equipment power, measuring data center energy efficiency; a PUE of 1.0 would mean every watt reaches IT equipment. Uptime Institute's annual survey has put the industry average near 1.56 in recent years, and new hyperscale facilities report far lower figures. PUE is a core efficiency metric in facility design and procurement.
- Uptime Institute Tier Classification
- A four-tier rating system (Tier I through Tier IV) defining data center site infrastructure topology and performance requirements. Many enterprise and financial services buyers look for Tier III (Concurrently Maintainable) design or certification, and Tier IV (Fault Tolerant) is less common.
- DTC (Direct-to-Chip) Cooling
- A liquid cooling architecture where coolant circulates through cold plates mounted directly on processors, extracting heat at the source. DTC is a common route for facilities moving from air cooling to liquid cooling to support high-density AI-compute racks.
- Immersion Cooling
- A thermal management approach that submerges entire servers in dielectric fluid, achieving superior thermal uniformity and supporting very high rack densities. Single-phase immersion uses a non-boiling fluid, while two-phase immersion uses the fluid's heat of vaporization to move more heat.
- CDU (Coolant Distribution Unit)
- The mechanical system that pumps, conditions, and distributes liquid coolant to server-level cold plates or immersion tanks, interfacing between the facility's chilled water loop and the IT equipment's thermal management system. CDU specifications (flow rate, delta-T, redundancy) are critical procurement evaluation parameters.
- CRAH (Computer Room Air Handler)
- A precision air conditioning unit designed specifically for data center environments that controls temperature, humidity, and airflow. CRAH units are the main cooling equipment in air-cooled facilities, and air cooling alone reaches its limits at high rack densities.
- Hot/Cold Aisle Containment
- An airflow management strategy that physically separates hot exhaust air from cold supply air using barriers, curtains, or enclosures. Containment improves cooling efficiency, but it cannot overcome the limits of air cooling for high-density AI-compute deployments.
- BESS (Battery Energy Storage System)
- An integrated battery system providing peak shaving, UPS ride-through capability, renewable energy time-shifting, and grid services revenue for data center facilities. BESS installations in data center applications are growing as facilities integrate storage for both resilience and economic optimization.
- Medium-Voltage Distribution
- Electrical distribution at 13.8kV, 15kV, or 35kV voltage levels now standard for hyperscale facilities consuming 200-500MW. Medium-voltage architecture reduces I²R losses compared to traditional 480VAC/208VAC distribution and requires switchgear, transformers, and bus duct systems previously associated with utility-grade infrastructure.
- 48VDC Power Architecture
- A direct current power distribution approach at 48 volts that reduces conversion losses compared with 12V rack power. Google and Facebook proposed a 48V Open Rack standard through the Open Compute Project in 2016, and hyperscale operators now use the approach for AI-compute facilities.
- Colocation
- A data center facility model where multiple tenants lease space, power, cooling, and connectivity infrastructure from a facility operator. Colocation providers (Equinix, Digital Realty, CyrusOne) compete for enterprise tenants through availability, connectivity, compliance certifications, and sustainability metrics.
- Hyperscale
- Data center facilities exceeding 100MW of critical IT load capacity, typically operated by cloud providers (AWS, Azure, Google) or large enterprises. Hyperscale procurement involves extended evaluation periods, with technical specifications governing every aspect of facility design, construction, and operations.
- Edge Computing
- A distributed computing paradigm that processes data closer to end users or IoT devices, reducing latency and bandwidth requirements. Edge data centers (1-5MW facilities) serve telecom operators, content delivery networks, and IoT platforms.
- N+1 Redundancy
- A reliability design principle where one additional component is provided beyond the minimum required for full system operation. Tier III designs typically use N+1 power and cooling, while Tier IV requires fault tolerance, usually through 2N systems.
- Commissioning Levels (L1-L5)
- The staged testing of a facility's systems, from factory witness tests at Level 1 through integrated systems testing at Level 5, which proves power and cooling systems work together under load and failure scenarios.
- EMR (Experience Modification Rate)
- An insurance rating that compares a contractor's workers' compensation claims with others in its trade; 1.0 is average and lower is better. Owners and EPCs use EMR, along with OSHA recordable rates, to screen contractors before award.
- DCIM (Data Center Infrastructure Management)
- Software that monitors, measures, manages, and controls data center facility infrastructure including power, cooling, physical space, and environmental conditions. DCIM platforms enable the operational intelligence that supports PUE optimization and capacity planning marketing narratives.
- Rear-Door Heat Exchanger (RDHx)
- A liquid cooling solution mounted on the rear door of a standard server cabinet that captures exhaust heat using chilled water coils. RDHx raises the density a standard rack can support without changing server hardware, which makes it a bridge between air cooling and full liquid cooling.
- Waste Heat Recapture
- The recovery and reuse of thermal energy generated by data center operations for district heating, industrial processes, or agricultural applications. Waste heat recapture transforms cooling from a cost center to a potential revenue generator and addresses ESG requirements in European and progressive US markets.
- ASHRAE TC 9.9
- The American Society of Heating, Refrigerating and Air-Conditioning Engineers Technical Committee responsible for establishing recommended and allowable environmental conditions for data center equipment. ASHRAE A1 through A4 thermal envelope specifications govern facility design parameters and equipment manufacturer warranties.