- UL 752
- The UL standard for bullet-resisting equipment: the materials, devices, assemblies, and fixtures used to build bullet-resisting barriers, such as panels, transaction windows, and package passers. The 12th edition (2023) replaced the earlier Levels 1 to 10 with designations such as UL-HG-A for handguns and UL-RF-A for rifles.
- ASTM F2656
- The ASTM standard test method for crash testing vehicle security barriers, such as bollards, gates, wedges, and walls, at perimeters and entry points. A rating states the impact condition tested and the penetration level reached.
- ASTM E119
- The ASTM standard test methods for fire tests of building construction and materials. It measures how long a wall, floor, roof, column, or beam contains a fire, keeps its structural integrity, or both, and results are stated as fire-resistance ratings in hours.
- UL 263
- The UL standard for fire tests of building construction and materials, developed, like ASTM E119, to simulate a building fire and rate assemblies by how long they resist it.
- UL 294
- The UL standard for access control system units: the construction, performance, and operation of equipment that controls entry to and exit from secured areas.
- Design Basis Threat (DBT)
- The threat a facility's protection is designed to resist. For nonmilitary federal facilities, the Interagency Security Committee publishes a Design-Basis Threat report, updated each year, that its countermeasure guidance is matched against.
- Facility Security Level (FSL)
- The security level the Interagency Security Committee's Risk Management Process standard assigns to a federal facility. The level drives the baseline countermeasures the facility is expected to have.
- Interagency Security Committee (ISC)
- The federal committee, chaired and supported by CISA, that sets physical security standards and best practices for nonmilitary federal facilities in the United States.
- Layered Security
- Protecting a site with several rings of measures, from the perimeter to the protected asset, so that detection, delay, and response work together and one failed measure does not leave the asset exposed.
- CPTED (Crime Prevention Through Environmental Design)
- A design approach that uses site layout, landscaping, lighting, and sight lines to discourage crime, commonly described through natural surveillance, natural access control, and territorial reinforcement.
- PIDS (Perimeter Intrusion Detection System)
- Sensors, such as fence-mounted, buried, radar, or video analytics, that detect and locate intrusion attempts along a site perimeter and alert a monitoring center.
- Anti-Ram Barrier
- A vehicle barrier, such as a crash-rated bollard, gate, wedge, or wall, designed to stop or slow a vehicle used as a weapon. Buyers usually ask for a rating under ASTM F2656.
- Forced-Entry Resistance
- A barrier's ability to delay a person trying to break through with tools. Doors, walls, and windows for high-security spaces are often specified for both forced-entry and ballistic resistance.
- Talk-Down System
- Speakers tied to video or intrusion detection that let monitoring staff, or a preset message, speak to a person on site after a detection, warning them before they reach the protected area.
- NERC CIP-014
- The NERC reliability standard for physical security of transmission stations and substations that, if rendered inoperable or damaged, could cause instability, uncontrolled separation, or cascading outages. CIP-014-3 is in effect; FERC approved CIP-014-4 in September 2026.
- GridSecCon
- The annual grid security conference hosted by NERC and the E-ISAC with a NERC Regional Entity, covering cyber and physical security of the electric grid.